UK Laboratory Services Ltd



WE HAVE MOVED


Please click on the link below to find our new website


Laboratory Services

Our trained, professional and experienced, multi-skilled engineers can service, repair, calibrate and validate a large range of medical and laboratory equipment, including laboratory centrifuges, incubators, ovens, freezers and water purifiers.

We offer services to the Health Care, Pharmaceutical and Food Industries as well as Academic Institutions. Periodic preventative maintenance and service contracts are available. All services are available without a service contract.

With technicians across the UK we can respond quickly to a breakdown

Laboratory Equipment Maintained

UK Laboratory Services repair and maintain laboratory equipment including:UK Laboratory Services repair and maintain laboratory equipment

other equipment serviced ...

Laboratory Service Engineers

UK Laboratory Services field service engineers have been trained with the following manufacturers:

  • Sanyo
  • Gallenkamp
  • Heraeus
  • Thermo Fisher
  • Sorvall and Eppendorf

and most other manufacturers

Customer Testimonials

Had engineer from UK laboratory services come in to repair and calibrate our sanyo gallenkamp ovens water jacketed co2 incubators, thermo herecell co2 incubators and a number of centrifuge units in our surrey and hampshire offices. Very pleased with service. Very professional.

Repair carried out to thermo fisher sorvall centrifuge. Motor replaced by engineer. Very quick response by company and excellent engineer.

Engineer fixed our eppendorf micro centrifuge machine. He also repaired our revco -80 fridge freezer by replacing the compressor and door seal. Great job done by engineer and company. Would have no problem in recommending them.

Calibration service call done by UK lab engineers on our sanyo gallenkamp and herecell 150i and 240i co2 incubator chambers. Also did service work to thermo fisher microplate readers and cell washers. They calibrated our forma 310 direct heat co2 incubators too. Very happy with overall service.

Thermo Scientific Cytomat 2 24 48 6000 and 6001 automated incubators all service and calibrated by UK lab services. Excellent work and professional engineers.

IQ OQ PQ carried out to our Heratherm incubator. Great service by company.

Herecell 150i and 240i incubator chamber repair and revco fridge freezer repair carried out by UK lab service at our Oxford laboratory. Very happy with work and engineers.

SANYO ORBITAL INCUBATOR MODEL MIR-220U repaired. Very good service.

Thermo fisher scientific Heraeus pico fresco labofuge multifuge biofuge stratos centrafuge and incubator repaired by UK lab engineer at our Kent London and Cambridge labs.

Thermo Fisher Scientific Wellwash AC Multidrop Combi Multiskan Spectrum serviced.
We got UK Laboratory Services engineers to repair and service our Thermo Fisher Scientific Wellwash AC Multidrop Combi and Multiskan Spectrum at our London and Harlow sites. Very pleased with work done. We have a number of eppendorf sorvall mse heraeus centrafuge units, sanyo thermo panasonic co2 incubators and water jacketed o2 incubators plus revco ult freezers and lec lms labcold labcaire fridges on pm contract too.

New brunswick, Labcold, Revco, Sanyo, Thermo, Panasonic ult freezer repairs
Engineers from UK Laboratory Services Ltd have over the years repaired our New Brunswick, thermo fisher scientific revco ult -80 fridge freezer and sanyo gallenkamp MDF-U5312 MDF-U334, MDF-U731, MDF-U731M, MDF-U500VX, Panasonic vip -86°C mdf-u76v Ultralow Freezer Laboratory Freezer along with LEC and labcold sparkfree ultf130, ultf301, ultf416, lulto480, lult2080, by PM and general servicing plus repair by replacing the compressor and door seal. IQ OQ PQ carried out to our Heratherm incubator. Great job done by engineer and company. Would have no problem in recommending them. Thermo Scientific Cytomat 2 24 48 6000 and 6001 automated incubators all serviced and calibrated by UK lab services too. Excellent work and professional engineers.

Service and repair work to incubators, centrafuge units, microplate readers and microplate washer.
Had engineers from UK laboratory services come in to repair and calibrate our sanyo gallenkamp ovens + Forma centrafuge units and incubators, 3110 370, 371, 380, 381, 3307, 3308, 3310, 3311, TC 120, IR 230, steri-cycle steri-cult + Heraeus heracell 150i, 240i, BB6220, BBD6220, cytoperm water jacketed co2 incubators & MCO-17AIC, MCO-18AIC, MCO 19AIC, MCO 20AIC incubators, sanyo orbital incubator MIR-220u thermo herecell co2 incubators and a number of centrifuge units refrigerated sorvall t6000, RT7, Stratos Biofuge, Legend rt, st16, st 40, 5c-rc plus, legend rt, evolution rc, rc-5c, Thermo fisher scientific Heraeus primo, pico, fresco, RC3, RC5b, RC6, eco mt135, eppendorf micro centrifuge machine. Also did service work to thermo fisher microplate readers multiskan fc ex floroskan ascent spectrum flash and thermo microplate cell washers wellwash nunc versa wellwash ac wellwash 4 mk2 in our oxfordshire, cambridgeshire, surrey, london and hampshire offices. Very pleased with service. Very professional.

Had UK lab services to various departments over the years to service following equipment.
Thermo Scientific Cytomat 2 24 48 6000 and 6001 automated incubators all service and calibrated by UK lab services. Excellent work and professional engineers. IQ OQ PQ carried out to our Heratherm incubator. Great service by company. Herecell 150i and 240i incubator chamber repair and revco fridge freezer repair carried out by UK lab service at our Oxford laboratory. Very happy with work and engineers. SANYO ORBITAL INCUBATOR MODEL MIR-220U repaired. Very good service. Thermo fisher scientific Heraeus pico fresco labofuge multifuge biofuge stratos centrafuge and incubator repaired by UK lab engineer at our london and cambridge labs. All my lab managers have expressed their appreciation for the great service UK lab Services Ltd have provided.

Sanyo gallenkamp Co2 incubators serviced and calibrated
I had my bank of 12 Sanyo gallenkamp Co2 incubators serviced and calibrated by uk lab services. Great job and all done on the same day. Excellent service.

Sanyo & Thermo incubator repair
Engineer from uk laboratory services repaired a sanyo gallenkamp and thermo fisher incubator. Very good service.

Thermo fisher Heraeus biofuge stratus centrifuge & Sorvall Legend refrigerated centrifuge repair
Thermo fisher Heraeus biofuge stratos centrifuge & Sorvall Legend refrigerated centrifuge repair. Got our Thermo fisher Heraeus biofuge stratus centrifuge & Sorvall Legend refrigerated centrifuge repaired calibrated and serviced by UK Laboratory Services of Oxfordshire. Our bank of centrifuge models a spread out between our Kent, Cambridgeshire, London and Oxfordshire laboratories. Our Thermo fisher Sorvall legend refrigerated models are at our Kent and London labs and thermo fisher heraeus biofuge stratos centrifuge at our Cambridge and Oxfordshire labs but this was not a problem to have them all covered on the one service contract with this company. Great service. Thermo fisher could not match the contract price for the Sorvall legend or heraeus biofuge stratos servicing.

Eppendorf centrifuge & MSE centrifuge repair service and calibration in Oxfordshire
We got our Eppendorf Microcentrifuge and bench top centrifuge models repaired serviced and calibrated last month by this company. Very good job done and speedy response to the breakdown. We will be taking out a PM contract with them soon an all or Eppendorf centrifuge models as well as some of our older MSE centrifuge models like our hawk, harrier and falcon models. Greta service thank you.

Thermo Fisher Sorvall Legend Centrifuge Repair in Cambridgeshire
Our company decided to try a different company to repair service and do calibrations on our batch of Thermo Fisher Sorvall Legend RT and 5C-RC refrigerated centrifuge machines because of cost cutting. We found UK Laboratory Services Ltd on Google and glad we did. They are cheaper then the main manufactures and can attend any break down calls a lot faster. We got or Thermo Fisher Sorvall Legend, RT, 5C Centrifuge Repair in Cambridgeshire. The engineer was trained by Sorvall centrifuge on all models. He did a great service on all Sorvall models and we now get them calibrated once a year by them also.

Sanyo Gallenkamp MCO 17 AIC CO2 incubator repair in Cambridgeshire
We got this company out to repair a Sanyo Gallenkamp MCO 17 AIC CO2 incubator at our Cambridgeshire laboratory. The co2 air pump had gone and the engineer fitted another. He then serviced and calibrated it. Sanyo Gallenkamp are now owned by Panasonic we believe so glad we found this company. Their engineer are trained on all co2 incubators from Sanyo.

Repair and Calibration to MSE Falcon 6/300r refrigerated centrifuge in Surrey
We love our MSE Falcon centrifuge machines right up until they broke down. We got a repair and Calibration to the MSE Falcon 6/300r refrigerated centrifuge in Surrey and Repair to the MSE Falcon 3/600 centrifuge in Kent. We had a refrigeration engineer repair the compressor on the Mse Falcon 3/600r refrigerated model and he also did a regas. Working great now. Our MSE Falcon centrifuge models are old but in good condition as we get them serviced on our pm contracts each year which we will be getting this company back to do soon as the annual service and calibration on both MSE falcon centrifuges are due.

MSE Harrier 18/80r plus refrigerated centrifuge repair service and calibration in Wiltshire
My MSE Harrier 18/80r plus refrigerated centrifuge kept running at full speed. We called an engineer from this company to fix it. He fitted a new sensor to the main motor and then serviced and calibrated it. Great job as parts for MSE harrier centrifuges are difficult to find as are engineers too. I dont think MSE are about any more as they were run by Sanyo Gallenkamp.

Repair & Calibration on a MSE Kestrel bench top centrifuge in UCL London
My MSE Kestrel Centrifuge went bang last week. Found this company on Google called UK Lab Services Ltd who said they repair and calibrate all MSE centrifuge Models. The engineer who Visited was very knowledgeable and helpful. He was actually trained by MSE at Sanyo. Not many MSE Kestrel centrifuge engineering company's about so glad we found this one. One other MSE centrifuge repair company was quoting almost double the cost to send an engineer out. This company is now set up on our system for future repairs as the dont just cover London but Oxfordshire and Cambridgeshire too, in fact as the engineer said to me they have engineers all over the UK. Great Job thank you.

MSE Micro Centaur Centrifuge & Centaur 2 Centrifuge Repair in Cambridgshire
We called UK Laboratory Services Ltd to repair and calibrate our MSE Micro Centaur Centrifuge & Centaur 2 Centrifuge Repair in our Cambridgeshire labs. They Both brike down within a week of each other. Our other laboratory is in Oxfordshire where the MSE Centaur 2 is located. This company sent out who fixed both MSE centrifuges on the same day at both addresses which was great. The MSE Centaur centrifuges are old but are so reliable we felt it better to get them repaired serviced and calibrated as we felt the new style centrifuges are not as good. Glad we found this company as their engineers a factory trained by Sanyo Gallenkamp who use to own MSE centrifuge and they said they can still get parts for nearly all MSE centrifuge models. Thank you UK lab Services.

Repair service calibrate MSE Harrier 18/80r refrigerated centrifuge and Hawk 15/05 centrifuge
We had an engineer out from Uk Laboratoty Services Ltd to repair service and calibrate our very old MSE Harrier 18/80r refrigerated centrifuge and Hawk 15/05 centrifuge machines. The engineer did a fantastic job and did a thorough service and calibration on both models after he did his repair. We got them back a few months later to repair a broken down MSE Falcon 300r refrigerated centrifuge and MSE Cellsep 720r refrigerated centrifuge floor standing model which had a cooling fault on the refrigeration side. Both MSE centrifuges again repaired and working well. Excellent find which I found on google.

MSE Hawk 15/05 centrifuge repair
Repair carried out to our MSE Hawk 15/05 centrifuge and MSE Harrier 18/80r at our Cambridgeshire site. Our MSE Harrier 18/80r centrifuge was repaired and serviced then calibrated on the same day by this company. Excellent service. They also repaired our MSE Hawk 15/05 centrifuge and MSE Falcon 6/300r centrifuge on other visits. We took out a service contract for preventative maintenance with them also and have been very pleased with overall support. MSE centrifuge repair engineers and companies are hard to find.

Liebherr fridge incubator & Nuaire glacier -86 ultralow temperature freezer Calibration.
Liebherr fridge incubator & Nuaire glacier -86 ultralow temperature freezer repair service & Calibration. Liebherr fridge incubator and Nuaire glacier -86 ultralow temperature freezer repair and service in London University hospital Pathology Lab. Uk Laboratory Services Ltd based in Oxfordshire did a excellent repair and service on our Liebherr fridge incubator cabinet and Nuaire glacier -86 ultralow temperature freezer at our London Laboratory. They fitted a new thermostat PCB to the Liebherr fridge incubator and did a full service and temperature check on the Nuaire glacier -86 ultralow temperature freezer. Great job thanks.

Eppendorf New Brunswick CO2 Incubator Shaker Repair in Oxford Laboratory.
Eppendorf New Brunswick CO2 Incubator Shaker Repair in Oxford Laboratory. We had our Eppendorf new brunswick co2 incubator shaker serviced, repaired and calibrated at our Oxford Laboratory last month. We have 6 Eppendorf Incubators and they all needed there yearly pm preventative maintenance done. Great job done by this company.

Thermo Fisher Scientific RapidStak Automated Microplate Stacker & Fluoroskan Ascent Microplate
Thermo Fisher Scientific RapidStak Automated Microplate Stacker & Fluoroskan Ascent Microplate Fluorometer microplate reader repair service and calibration. Thermo Fisher Scientific RapidStak Automated Microplate Stacker & Fluoroskan Ascent Microplate Fluorometer microplate reader serviced and calibrated by UK lab services. Very good service by this company. They have done work for us before to our ultra low temperature freezers and co2 incubators. Good company.

Thermo Fisher Scientific Revco ultralow temperature -86 freezer breakdown in our Hospital
Thermo Fisher Scientific Revco ultralow temperature -86 freezer breakdown in our Hospital Pathology Lab in Suffolk. Thermo Fisher Scientific Revco ultralow temperature -86 freezer breakdown in our Hospital Pathology Lab in Suffolk. Our Thermo Fisher Scientific Revco ultra low temperature -86 freezer broke down. Our CO2 back up system kicked in to save our samples. Engineer from UK lab Services came out to us the next day as it was an emergency. He fixed it that day. Great service and price of repair was good too compared to Thermo Fisher Scientific Revco ultralow temperature freezer engineers.

Thermo Fisher Scientific Heraeus Multifuge Centrifuge repair & service Berkshire Laboratory.
Thermo Fisher Scientific Heraeus Multifuge Centrifuge repair & service Berkshire Laboratory. Thermo Scientific Heraeus Multifuge Centrifuge repair, calibration and service in Berkshire Laboratory.. We prepare cell culture, microplate, bioproduction, blood separation and microbiology with the Thermo Scientific Heraeus Multifuge Centrifuge Series in our pathology laboratories in Berkshire. We get a range of rotors and adapters, including lightweight Thermo Scientific Fiberlite carbon fiber rotors, checked each year with this company. They service and calibrate a wide range of Thermo Scientific Heraeus Multifuge Centrifuges for us. Very good company.

Ultra-low Temperature Panasonic VIP -86C Laboratory Freezer repair in Oxfordshire Laboratory.
Ultra-low Temperature Panasonic VIP -86C Laboratory Freezer repair in Oxfordshire Laboratory. Panasonic Ultra-low Temperature VIP -86C Laboratory Freezer repair carried out at our Oxfordshire Pathology Laboratory. We got a refrigeration engineer out to regas our Panasonic Ultra-low Temperature VIP -86C Laboratory Freezer. Very happy with his work and the speedy response to our breakdown as the freezer was on CO2 back up until the repair was finished. We have 4 Panasonic Ultra-low Temperature VIP -86C Laboratory Freezers installed at our Oxfordshire Laboratory a few years ago and this was the first breakdown we had as they are very well built ult freezers. thank you for a good service.

Ultra-low Temperature Panasonic VIP -86C Laboratory Freezer repair in Oxfordshire Laboratory.
Ultra-low Temperature Panasonic VIP -86C Laboratory Freezer repair in Oxfordshire Laboratory. Panasonic Ultra-low Temperature VIP -86C Laboratory Freezer repair carried out at our Oxfordshire Pathology Laboratory. We got a refrigeration engineer out to regas our Panasonic Ultra-low Temperature VIP -86C Laboratory Freezer. Very happy with his work and the speedy response to our breakdown as the freezer was on CO2 back up until the repair was finished. We have 4 Panasonic Ultra-low Temperature VIP -86C Laboratory Freezers installed at our Oxfordshire Laboratory a few years ago and this was the first breakdown we had as they are very well built ult freezers. thank you for a good service.

Eppendorf centrifuge & Sanyo MSE centrifuge repair service & calibration in Hampshire.
Eppendorf centrifuge & Sanyo MSE centrifuge repair service & calibration in Hampshire. We had our Eppendorf Micro centrifuge and Sanyo Gallenkamp MSE bench top Hawk & Harrier centrifuge models repaired serviced and calibrated last month at our hospital pathology laboratory by this company. Excellent work done and speedy response to the breakdown. We will be taking out a PM contract with them soon an all our Eppendorf centrifuge models as well as some of our older Sanyo Gallenkamp MSE centrifuge models like our hawk, harrier and falcon models. We have used Eppendorf and Sanyo Gallenkamp MSE engineers before who I think are now Panasonic or Weiss Technik, but they are more costly and sometimes you can wait a few weeks for an engineers visit. Great service thank you.

Dometic medical Blood Bank Refrigerator repairs at Southampton Hospital Pathology Lab.
Dometic medical Blood Bank Refrigerator repairs at Southampton Hospital Pathology Lab. We had our 3 Dometic medical Blood Bank Refrigerator repaired and serviced as well as calibrated at Southampton Hospital Pathology Laboratory. Very pleased with the work this Lab repair company did for us. Our Dometic medical Blood Bank Refrigerators are critical to our work and we must have them working well all year round. We will be putting the 3 Dometic medical Blood Bank Refrigerators on service PM preventative maintenance contract with this company who look after co2 incubators and centrifuges in the Southampton hospital.

LEC Labcold Cooled Incubator Medical Fridge Refrigeration Chamber Repair in Devon Laboratory.
LEC Labcold Cooled Incubator Medical Fridge Refrigeration Chamber Repair in Devon Laboratory. We had 8 LEC Labcold Cooled Incubator Medical Fridge Refrigeration Chamber Repaired in Devon Pathology Laboratory last month by UK Laboratory Services Ltd. They did all 8 repairs and service in one day. There prices are much better then the main manufacturer Lec too. We will also use them to calibrate another 5 LEC Labcold Cooled Incubator Medical Fridge Refrigeration Chambers at our other pathology Laboratory in Cornwall.

Sanyo Gallenkamp MSE centaur 2 centrifuge and MCO 17 aic CO2 incubator repair & calibration.
Sanyo Gallenkamp MSE centaur 2 centrifuge and MCO 17 aic CO2 incubator repair & calibration. Happy with the service this company gave us at out London University hospital Pathology department on our Sanyo Gallenkamp MSE centaur 2 centrifuge and MCO 17 aic CO2 incubator. They did a repair & calibration to both units. Working fine now.

Leec CO2 incubator & Revco ultra low -86 freezer repair in Coventry, Birmingham Warwickshire.
Leec CO2 incubator & Revco ultra low -86 freezer repair in Coventry near Birmingham Warwickshire. Very impressed with the support this company has given our Pathology Laboratories over the past year. They have serviced repaired, carried out pm preventative maintenance work and calibrations on our range of Leec CO2 incubators & Revco ultra low -86 freezers at our Coventry laboratory's near Birmingham Warwickshire.read less

Thermo Fisher Scientific Forma CO2 Incubator & Forma IR 230 Incubator Repair in Berkshire
Thermo Fisher Scientific Forma CO2 Incubator & Forma IR 230 Incubator Repair in Berkshire. Repair to Thermo Fisher Scientific Forma CO2 Incubator & Forma IR 230 CO2 water jacketed Incubator in Berkshire. The Engineer repaired and calibrated our 4 Thermo Fisher Scientific Forma incubators. Excellent work done. One of the Forma Incubators needed a CO2 valve but most just needed servicing and calibrating. We have had Thermo Fisher Scientific Forma CO2 incubators off Thermo Fisher Scientific now for years as they are very reliable. Thank you UK Lab Services.

Eppendorf New Brunswick Galaxy 48R CO2 Incubator repair, service and calibration in Birmingham.
Eppendorf New Brunswick Galaxy 48R CO2 Incubator repair, service and calibration in Birmingham hospital pathology laboratory near Warwickshire west midlands. An engineer from UK Laboratory Services Ltd who are based in Oxfordshire repaired, serviced and calibrated our 3 Eppendorf New Brunswick Galaxy 48R CO2 Incubator. Only one had a fault and the other 2 just needed a service and calibration. They have repaired other Eppendorf New Brunswick Galaxy 48R CO2 Incubators at our other pathology laboratory's in Coventry last year and did a great job so we would recommend them.

LMS cooled incubator & Thermo Heraeus Kelvitron drying vacuum oven service in Surrey.
LMS cooled incubator & Thermo Heraeus Kelvitron drying vacuum oven service & calibration Surrey. Service and calibration yearly preventative maintenance checks were carried out on our LMS cooled incubator & Thermo Heraeu Kelvitron drying vacuum ovens at our surrey laboratorys. UK laboratory Services did a splendid job. We use them every year and recommend them to other company's in the industry.

Sanyo Panasonic -86 ultralow temperature freezer service by UK Lab Services in Oxfordshire.
Sanyo Panasonic -86 ultralow temperature freezer service by UK Lab Services in Oxfordshire. We had a yearly PM preventative maintenance service carried on our 6 Sanyo Panasonic -86 ultralow temperature freezers by UK Lab Services in our pathology laboratory's Oxfordshire. They were all serviced within a few hours by a very good engineer. This company was cheaper then going to Sanyo for one of their -86 ultra low temperature freezer engineers or I think they are called Panasonic now. Thank you.